🔸Target Flowmeter

🔹 Pipe-mounted Target Flow Meter

The XY Series Smart Target Flow Meter represents the third generation of capacitive force sensing flow meters, developed based on traditional force sensors and leveraging advancements in new sensor technologies and electronics. Compared to previous mechanical force sensors and strain gauge sensors, it offers significantly enhanced performance, featuring high sensitivity, accuracy, and impact resistance!

Definition

A target-type flowmeter is an instrument that measures flow based on the force exerted by a fluid on a target plate, classified as a velocity-type flowmeter.


Working Principle

Fluid flow impacts the target plate, with the force exerted on the plate being proportional to the fluid's kinetic energy. According to Newton's Second Law, the magnitude of the force is proportional to the square of the fluid velocity. By measuring the force on the target plate and performing conversion calculations, the fluid flow rate is determined.


Structure

Primarily consists of a measuring pipe section, target plate, force sensor, and display instrument. The measuring pipe provides the fluid passageway. The target plate, mounted inside the pipe, senses the fluid force. The force sensor converts the force signal into an electrical signal, which the display instrument processes and presents as the flow rate value.


Advantages

- Wide Applicability: Measures various fluids, including high-viscosity and particulate-laden fluids.

- Low Installation Requirements: Requires minimal upstream/downstream straight pipe lengths compared to other flowmeters.

- Simple Structure: No complex moving parts, ensuring high reliability and easy maintenance.


Disadvantages

- Limited accuracy: Measurement accuracy typically ranges from ±1% to ±3%, which is relatively low compared to some high-precision flow meters.

- Narrow turndown ratio: The turndown ratio is usually between 3:1 and 10:1, offering a limited range.

Applications

Widely used in petroleum, chemical, metallurgical, power, food, and other industries to measure the flow of various liquids, gases, and steam.

 

 

 

 


Product Name: Target Flow Meter

Applicable Media: Gas, Liquid, Steam

Pipe Diameter (DN): DN15 to DN300mm (Pipe-mounted), DN150 to DN3000mm and larger (Insertion-type), Rectangular Ducts

Nominal Pressure: 0.6 to 42MPa (Refers to nominal pressure of connecting flanges, not working pressure of the medium)

Operating Temperature: -200 to +600°C (Contact factory for higher temperatures)

Measurement Accuracy: ±0.5%, ±1.0%, ±1.5% FS

Turndown Ratio: 1:10; 1:15

Housing Material: Carbon Steel; Stainless Steel;

Power Supply: Built-in 3.6VDC Lithium Battery (2-year lifespan); External 24VDC;

Output Signal: 4–20mA Two-Wire System; Pulse 0–1000Hz; RS485

Protection Rating: IP65; IP67

Explosion-proof Marking: Intrinsically safe ExiallCT6; Flameproof ExdllCT6

Display: Cumulative flow; Instantaneous flow; Percentage of full scale; Operating pressure; Operating temperature; Self-diagnostic faults

Connection: Pipe flange (DN15-300mm); Insertion (DN150-N6000mm and larger)

Installation Requirements: Can be installed horizontally or vertically; straight pipe runs before and after should meet 10D upstream and 5D downstream (D = nominal diameter)

Special Connections: Threaded (DN<50mm); clamp-on (DN<300mm); online disassembly type; (specify when ordering special connections)

 

 

 


Pre-Installation Preparation

1. Inspect the instrument: Verify that the specifications and model of the target-type flowmeter match design requirements. Ensure no external damage and that all accessories are present. Check for deformation of the target plate and confirm the force sensor functions normally.

2. Pipe Cleaning: Thoroughly remove debris, welding slag, rust, and other contaminants from the pipeline to prevent them from entering the flowmeter, which could affect measurement accuracy or damage the instrument.


Installation Location Selection


1. Straight Pipe Section Requirements: Install on straight pipe sections whenever possible. The upstream straight pipe section should be at least 5 times the pipe diameter, and the downstream section at least 3 times the pipe diameter to ensure stable fluid flow and improve measurement accuracy.

2. Avoid Interference: Position away from equipment causing vibration or pressure fluctuations (e.g., pumps, compressors) and steer clear of areas with strong electromagnetic fields.

3. Maintenance Accessibility: Select a location facilitating installation, commissioning, maintenance, and repairs, ensuring sufficient surrounding clearance.


Installation Methods

1. Horizontal Installation: Suitable for most fluids. Ensure the flowmeter's axis aligns with the pipeline axis to guarantee uniform fluid flow over the target plate.

Connection and Fixing

1. Flange Connection: Align the flowmeter flange with the pipeline flange. Use a sealing gasket and evenly tighten bolts to ensure a leak-free connection.

2. Welded Connection: Implement cooling measures during welding to protect the flowmeter and prevent internal component damage from overheating. Remove slag after welding and inspect weld quality.

Electrical Connection

1. Wiring: Connect wires according to the manual, ensuring correct power and signal line connections to avoid instrument damage from miswiring.

2. Grounding: Establish proper grounding with resistance meeting specifications to prevent electromagnetic interference and ensure stable measurement.

Post-Installation Inspection

1. Seal Integrity Test: Conduct pipeline pressure testing to verify no leaks at the flowmeter-pipeline connection.

2. Instrument Calibration: Apply power, verify normal display operation, and perform zero calibration and range adjustment.




Selection

- Medium Characteristics: Consider fluid temperature, pressure, corrosiveness, viscosity, and presence of particulate impurities. For high-viscosity fluids, select appropriate specifications; for highly corrosive fluids, choose corrosion-resistant materials.

- Flow Range: Based on actual flow rate and variation range, select a flowmeter with matching capacity to ensure measured values fall within 30%–100% of the range.

- Accuracy Requirements: Select a target-type flowmeter with the corresponding accuracy class based on industrial production's flow measurement precision requirements.


Installation

- Straight Pipe Section Requirements: Ensure a sufficient length of straight pipe sections before and after the installation point—typically 5 times the pipe diameter upstream and 3 times downstream—to guarantee fluid stability.

- Avoid Interference: Keep away from vibration sources like pumps and compressors, as well as strong electromagnetic interference equipment such as frequency converters and transformers.

- Installation Position: For horizontal installation, ensure the flow meter's axis aligns with the pipeline's axis.


Operation and Maintenance

- Start-up and Shutdown: During start-up, open the bypass valve first, then slowly open the upstream and downstream valves of the flow meter. During shutdown, close the upstream and downstream valves of the flow meter first, then close the bypass valve.

- Regular Inspection: Periodically inspect the instrument's appearance, connection components, and sealing performance. Check the target plate for wear or deformation, and promptly clean pipeline impurities.

- Calibration: Calibrate at specified intervals to ensure measurement accuracy. Recalibrate immediately if significant measurement deviations occur during operation.

Troubleshooting

- Abnormal Flow: If flow readings are unusually high or low, inspect for pipeline leaks or blockages, check for loose instrument wiring, and verify sensor integrity.

- Unstable Signal: Address significant signal fluctuations by investigating electromagnetic interference, ensuring proper grounding, and confirming stable fluid flow within the pipeline.




厦仪科技(南安)有限公司XY1 Series Target Flowmeter production manual.pdf


关联内容